Case Report

Pulling out of the Urinary Catheter together with Double-J Stent which is Penetrated to the Tip of the Foley after a Renal Transplantation: A Case Report

Volume 22 · Issue 2 Publish Date: February 6, 2019
Full Text PDF
Ahmet Burak ÇİFTCİ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Fahri YETİŞİR
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Mehmet TOKAÇ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Alper Bilal ÖZKARDEŞ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Mehmet Deniz AYLI
Atatürk Eğitim ve Araştırma Hastanesi, Nefroloji Kliniği, Ankara, Türkiye
Mehmet KILIÇ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
ÇİFTCİ, A. B., YETİŞİR, F., TOKAÇ, M., ÖZKARDEŞ, A. B., AYLI, M. D., & KILIÇ, M. (2019). Pulling out of the Urinary Catheter together with Double-J Stent which is Penetrated to the Tip of the Foley after a Renal Transplantation: A Case Report. Turkish Journal of Nephrology, 22(2), 231–233. Retrieved from https://www.turkjnephrol.org/index.php/pub/article/view/877
Full Text Full Text PDF

Abstract

Today kidney transplantation is the best treatment choice of end stage renal failure. Double-j catheters have been used in renal transplant patients to prevent urinary leakage and ureteric obstruction but these catheters have many complications like urinary tract infection, obstruction, catheter encrustation, perforation and migration. Although these complications, double-j catheters are now widely used in urological practice. Yet there is controversy among transplant surgeons in the routine use of these catheters.

A case of renal transplant patient whose double-j catheter’s distal end was mistakenly penetrated to the tip of the bladder foley catheter is reported. Because of that, the double-j catheter was taken out with the foley catheter at the postoperative early period. The use of 26 cm length double-j catheter by cutting its bladder side for making it suitable to the operation area is thought to be an important factor which made this complication possible. This very rare case was examined in view of the literature. In conclusion, it is thought that the use of appropriate size and length of double-j catheters without cutting any part and without destroying the “j” formation will decrease these complications in renal transplant patients.

Similar Articles

Article Info
Published In
Journal Turkish Journal of Nephrology
Volume / Issue Volume 22 · Issue 2
Pages 231-233
History
Published Online February 6, 2019
Copyright
Affiliations
Ahmet Burak ÇİFTCİ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Fahri YETİŞİR
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Mehmet TOKAÇ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Alper Bilal ÖZKARDEŞ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Mehmet Deniz AYLI
Atatürk Eğitim ve Araştırma Hastanesi, Nefroloji Kliniği, Ankara, Türkiye
Mehmet KILIÇ
Atatürk Eğitim ve Araştırma Hastanesi, Genel Cerrahi Kliniği, Ankara, Türkiye
Cite this Article
ÇİFTCİ, A. B., YETİŞİR, F., TOKAÇ, M., ÖZKARDEŞ, A. B., AYLI, M. D., & KILIÇ, M. (2019). Pulling out of the Urinary Catheter together with Double-J Stent which is Penetrated to the Tip of the Foley after a Renal Transplantation: A Case Report. Turkish Journal of Nephrology, 22(2), 231–233. Retrieved from https://www.turkjnephrol.org/index.php/pub/article/view/877
Outlines